DW712N | SIERRA CONICA Type 4
Datos generales
Identificador de tipo | 4 |
Estado | Discontinued |
Estado de instrucciones de reparación | Repair |
Última fecha de fabricación | 8/30/2019 |
Cambiar ubicación Spain, Europe
Identificador de tipo | 4 |
Estado | Discontinued |
Estado de instrucciones de reparación | Repair |
Última fecha de fabricación | 8/30/2019 |
Atributo técnico | Valor | Unidad | Código |
---|---|---|---|
NO LOAD AMPS 230V | 2.2-4.3 | A | |
LOAD AMPS 115V | 4.8-9.0 | A | |
Armature Resistance 115V | 0.280 | Ω | |
Armature Resistance 230V | 1.155 | Ω | |
Field Resistance 115V | 0.170 | Ω | |
Field Resistance 230V | 0.920 | Ω | |
Input Watts | 1600 | W | |
No load speed | 5400 | RPM | |
Initial Brush Length | 21.5 | mm | |
BRUSH LIFE | TBA | mm/hrs | |
Static Sensitive | Y | N/A | |
FLASH TEST DURATION | 1 | s | |
FLASH TEST VOLTAGE | 4k | kV | |
VIBRATION EN 60745 | 2.1 | User manual | |
CE Lpa SOUND PRESSURE | 91 | dB | |
Kpa Sound Pressure Uncertainty | 3.0 | dB | |
CE Lwa ACOUSTIC POWER | 104 | dB | |
Kwa Acoustic Power Uncertainty | 2.9 | dB | |
BLADE BORE | 30 | mm | |
BLADE SIZE | 216 | cm | |
Date Code Location | Item 71 | N/A |